Because of the burner main fuel divided into natural gas, liquefied petroleum gas, city gas and other combustible gas, the various fuels is inflammable and explosive dangerous gas, in the use and storage of all deal with security cause height to take seriously, otherwise there will be major safety accident.
(a), the boot operation:
1. To install a new furnace body, debugging should be carefully tested and gas burner meets the requirements; check the gas supply pipeline detection equipment is normal and pipeline valve opening and closing is normal, whether for future use and maintenance.
2 new installation of the pipeline, should seriously check the installation of all piping reliability and pipeline sealing.
3 the use of separate gasification station users, to ensure that the amount of gas supply, gas supply parameters to meet the requirements of safe combustion.
4 operating personnel to read the equipment manual, familiar with the safe operation of knowledge and methods.
5 check before starting the gas valve is open, otherwise the burner does not work.
6. Start control cabinet of the power control button, at this time digital display shows the furnace temperature, the new installed the temperature of the oven body is environment temperature.
7. Start the blower control button, installed in the furnace body fan work. At this point, if the wind machine damage control cabinet automatic protection not to enter the next step.
8. The combustion air fan work no abnormal phenomenon, and then start the combustion control button when burning the controller program began to work, it through certain procedures of ignition, aspirated, flame detection, such as final program for safety combustion.
9 when the combustion controller receives the signal which is not conducive to combustion (such as: ignition failure, gas pressure is not stable, the circuit has a problem) and other issues, the combustion controller immediately shut off the gas and send an alarm signal.
10 Zhengzhou burner controller if the alarm, must be resolved after the failure of the operator to manually reset it can continue to work.
11 the operation of the whole equipment, operators should refer to the furnace body safety operation procedures and production process requirements for operation.
12 according to the production process requirements need to adjust the temperature control, the operator should refer to the Intelligent NC table specification for adjustment.
(two) the burner parts department to teach you to shut down operation:
(1) there are two kinds of situations: first, when the furnace temperature reaches the set value automatically shut down, the operator does not have any operation, wait until the furnace temperature below the set value, the controller will automatically boot.
(2) the second is artificially machine and shift down. At this time, the operator should be in the boot of the reverse order (A. first closed combustion control button, B. and then close the fan button, C. finally shut down the power button) shutdown operation.
(3) the operator should shut off the gas pipeline valve in the case of long shut down time, so as to avoid the gas leakage.